Panel Kontrol Notifier RP-2002Notifier RP-2002, 6 Zone Fire Alarm Control Panel merupakan seri panel kontrol fire alarm konvensional yang banyak digunakan sebagai agent releasing control panel pada fire suppression system seperti FM200 system, Novec 1230 fire system, CO2 fire suppression system, inert gas fire suppression system dll.

The RP-2002 is a six-zone FACP for single and dual hazard agent releasing applications. The RP-2002 provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring agent-based releasing. The RP-2002 is compatible with System Sensor’s i3 detectors which are conventional smoke detectors that can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory ‘freeze’ signal when the ambient temperature falls below the detector rating of approximately 45°F (7.22°C). In addition, the control panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Refer to the Notifier Device Compatibility Document for a complete listing of compatible devices.

Four outputs are programmable as NACs (Notification Appliance Circuits) or releasing circuits. Three programmable Form-C relays (factory programmed for Alarm, Trouble and Supervisory) and 24 VDC special application resettable and non-resettable power outputs are also included on the main circuit board. The RP-2002 supervises all wiring, AC voltage, battery charger and battery level.

Activation of a compatible smoke detector or any normally open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicator, display alarm information
on the panel’s LCD, sound the piezo sounder at the FACP, activate the FACP alarm relay and operate an optional module used to notify a remote station or initiate an auxiliary control function.

The Notifier RP-2002E conventional fire releasing agent control panel offers the same features as the RP-2002 but allows connection to 220/240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 110/
120 VAC and 220/240 VAC versions of the panels.

Features Notifier RP-2002

  • Listed to UL Standard 864, 9th edition.
  • FM Approved.
  • Designed for agent releasing standards NFPA 12, 12A, 12B, and 2001.
  • Meets International Building Code (IBC) seismic requirements.
  • Disable/Enable control per input zone and output zone.
  • Extensive transient protection.
  • Dual hazard operation.
  • Adjustable pre-discharge, discharge and waterflow delay
    timers.
  • Cross-zone (double-interlock) capability.
  • Six programmable Style B (Class B) IDCs (Initiating Device
    Circuit).
  • System Sensor i3 series detector compatible.
  • Four programmable Style Y (Class B) output circuits - (special application power).
  • Strobe synchronization:
    – System Sensor
    – Wheelock
  • – Gentex
    – Faraday
    – Amseco
  • Three programmable Form-C relays.
  • 7.0 amps total 24 VDC output current.
  • Resettable and non-resettable output power.
  • Built-in Programmer.
  • ANN-BUS connector for communication with optional devices (up to 8 total of any of the following):

– N-ANN-80 Remote LCD Annunciator
– N-ANN-I/O LED Driver
– N-ANN-S/PG Printer Module
– N-ANN-RLY Relay Module
– N-ANN-LED Annunciator Module

  • 80-character LCD display (backlit).
  • Real-time clock/calendar with daylight savings time control.
  • History log with 256 event storage.
  • Piezo sounder for alarm, trouble and supervisory.
  • 24 volt operation.
  • Low AC voltage sense.
  • Outputs Programmable for: – Releasing Circuits or NACS
  • NACs programmable for:

– Silence Inhibit
– Auto-Silence
– Strobe Synchronization
– Selective Silence (horn-strobe mute)
– Temporal or Steady Signal
– Silenceable or Non-silenceable
– Release Stage Sounder

  • Automatic battery charger with charger supervision.
  • Optional Dress Panel DP-51050 (red).
  • Optional Trim Ring TR-CE (red) for semi-flush mounting the cabinet.
  • Optional N-CAC-5X Class A Converter Module for Outputs and IDCs.
  • Optional 4XTM Municipal Box Transmitter Module.
  • Optional Digital Alarm Communicators (411, 411UD, 411UDAC).
  • Optional ANN-SEC card for a secondary ANN-BUS.

Spesifikasi Notifier RP-2002

  • RP-2002 (FLPS-7 Power Supply): 120 VAC, 60 Hz, 3.66 amps
  • RP-2002E (FLPS-7 Power Supply): 240 VAC, 50 Hz, 2.085 amps
  • Wire size: minimum 14 AWG (2.0 mm²) with 600 V insulation, supervised, nonpower-limited
  • Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep.
  • Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep.
  • Trim Ring (TR- CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide.
  • Shipping Dimensions:
    – Height 20.00" (50.80cm)
    – Width 22.50" (57.15cm)
    – Depth 8.50" (21.59cm)
  • Temperature and Humidity Ranges: This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F.

Agency Listings and Approvals Notifier RP-2002

The listings and approvals below apply to the basic RP-2002(E) control panels. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.

  • UL: S635
  • FM approved
  • CSFM: 7165-0028:0245
  • MEA: 333-07-E
  • Seismic Listing: Reference certificiate of compliance VMA - 45894-01 by the VMC Group

Brosur dan Datasheet Notifier RP-2002

Download Brosur Notifier RP-2002, 6 Zone Fire Alarm Control Panel disini untuk mendapatkan informasi lebih lanjut

Harga Notifier RP-2002

Kami menjual Panel Kontrol Fire Suppression System Notifier RP-2002 dengan harga distributor. Harga Notifier RP-2002, 6 Zone Fire Alarm Control Panel yang kami jual sangat murah dan bersaing dari distributor Notifier langsung di Indonesia dan terpercaya. Jika Anda sedang mencari Control Panel Fire Alarm Notifier RP-2002 bisa langsung menghubungi kami di 081317698478, 087701989383 untuk mendapatkan harga terbaik. Telepon atau WhatsApp untuk harga terbaik.

Harga Kontrol Panel Notifier RP-2002Tanya Harga Kontrol Panel Notifier RP-2002

Read 2473 times Last modified on Monday, 08 March 2021 10:36
Administrator

Fire Engineer sekaligus Praktisi yang berpengalaman dibidang sistem pemadam kebakaran dan telah mengerjakan berbagai macam proyek Sistem Pemadam Kebakaran, juga ikut bergabung sebagai member aktif di NFPA

Leave a comment

Make sure you enter all the required information, indicated by an asterisk (*). HTML code is not allowed.

Sistim Pendeteksi Kebakaran

©2019. Semua Hak Cipta Dilindungi Undang-undang. PT. GLOBAL PROTEKSI NUSANTARA