• 0813-1769-8478
  • 0889-2129-515
  • This email address is being protected from spambots. You need JavaScript enabled to view it.

Displaying items by tag: panel FM200

Tuesday, 23 April 2024 08:00

FIRESOL® HFC-227ea Fire Suppression System

FIRESOL HFC-227ea Fire Suppression SystemFIRESOL® HFC-227ea Fire Suppression System adalah sistem pemadam api otomatis yang menggunakan gas clean agent HFC-227ea atau gas FM200 sebagai media pemadam api nya. FIRESOL® merupakan salah satu merek produk pemadam kebakaran yang diproduksi atau dirakit oleh PT. Global Proteksi Nusantara sesuai dengan standar Nasional maupun standar Internasional. Peralatan sistem pemadam api FIRESOL® HFC-227ea Fire Suppression System dirancang secara khusus untuk dapat mencegah dan menanggulangi kebakaran pada ruangan yang berisi peralatan penting, mengikuti kaidah perancangan dan desain sesuai dengan ketentuan, kode dan standar yang berlaku dan telah melalui uji coba serta memiliki sertifikat yang diakui secara Nasional maupun Internasional.

FIRESOL® HFC-227ea Fire Suppression System merupakan sistem pemadam kebakaran yang menggabungkan perangkat mekanikal, elektrikal, fire alarm system dan control system menjadi satu sistem proteksi kebakaran yang terintegrasi dan dapat bekerja secara otomatis maupun secara manual. Media pemadam Clean Agent HFC-227ea adalah salah satu media pemadam yang sangat efektif untuk memadamkan kebakaran kelas C yaitu kebakaran yang diakibatkan oleh peralatan listrik atau peralatan elektronik.

Panel Kontrol Notifier RP-2002Notifier RP-2002, 6 Zone Fire Alarm Control Panel merupakan seri panel kontrol fire alarm konvensional yang banyak digunakan sebagai agent releasing control panel pada fire suppression system seperti FM200 system, Novec 1230 fire system, CO2 fire suppression system, inert gas fire suppression system dll.

The RP-2002 is a six-zone FACP for single and dual hazard agent releasing applications. The RP-2002 provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring agent-based releasing. The RP-2002 is compatible with System Sensor’s i3 detectors which are conventional smoke detectors that can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory ‘freeze’ signal when the ambient temperature falls below the detector rating of approximately 45°F (7.22°C). In addition, the control panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Refer to the Notifier Device Compatibility Document for a complete listing of compatible devices.

Published in Fire Alarm System

Panel Context Plus EP203Introducing the EP203/CON 3 zone automatic extinguisher panel from Context Plus. LPCB certified to EN 12094 part 1 (Fixed Firefighting Systems - Components for Gas Extinguishing Systems) and EN54 parts 2 & 4, the panel epitomises quality, durability and reliability and is ideal for use in any area housing expensive, dangerous or irreplaceable items of equipment.

Featuring an intuitive 128 x 64 pixel two-colour graphic display that gives clear and concise feedback to the user, installer and commissioning engineer, the panel also includes six monitored inputs (including hold and abort), a time stamped log, adjustable flood times and volt-free changeover relays for fire, local fire, 1st stage active, 2nd stage active, extractor fan and fault.

©2019. Semua Hak Cipta Dilindungi Undang-undang. PT. GLOBAL PROTEKSI NUSANTARA